Load Cells - EST-4 Single Point Load Cell


EST-4 Technical Information

EST-4EST-4

Hover over image to enlarge
EST-4
Compression Load Cell
Rated Load (kg) A B C D E F
50, 100, 150, 200 156 75 50 44 24 M12 X 1.75 600 X 600
250, 500 146 95 70 60 36 M12 X 1.75 800 X 600
750, 1000, 1500, 2000 176 125 95 76 46 M16 X 2 1200 X 1200
EST-4 DiagramEST-4 Diagram

Hover over image to enlarge
Parameter Unit Specification
Sensitivity mV/V 2 +/- 0.1
Nonlinearity % FS +/- 0.02
Hysterisis
Repeatability %FS 0.01
Creep %FS/30 min +/- 0.02
Zero Balance %FS +/- 1
Zero Temperature Coefficient %FS/10°C +/- 0.02
Rated Output Temperature Coefficient %FS/10°C
Input Resistance Ω 420 +/- 10
Output Resistance Ω 350 +/- 3
Insulation Resistance ≥5000
Supply Voltage V 10 (DC / AC) MAX: 15 (DC / AC)
Temperature Compensation Range °C -10~+50
Safe Temperature Range °C -20~+60
Safe Overload %FS 120
Cable mm Ø5 x 3000
Cable Colour Code Input: Red (+) Black (-) Output: Green (+) White (-)